fan conversion 66 f-100

The place to talk Slicks. All we ask is that discussion has something to do with slicks...

Moderators: Casey 65, Kid

Post Reply
oldschool J
Posts: 4
Joined: January 9, 2013, 2:40 pm

fan conversion 66 f-100

Post by oldschool J »

I need advice on what dual electric fans & shroud will fit my stock radiator.(1966 f-100 with 390 engine) Any help would be appreciated. Jerry
User avatar
Casey 65
Posts: 1883
Joined: April 3, 2006, 1:42 pm
Location: Kansas City, Missouri
United States of America

Re: fan conversion 66 f-100

Post by Casey 65 »

It is recommended that the fans cover a minimum of 73% of the area of the radiator. I tried with less and had undesirable results. Added fans and shroud and the results were excelent. I used a 16" fan and two 8" fans with a flat aluminum shroud. I would not recommend attaching the fans to the radiator! I had that setup once and the fan failed and chewed up the radiator. You can build a shroud much cheaper than the cost of a new radiator. Good luck.
"One Test Result is Worth One Thousand Expert Opinions" - Werner von Braun
Leeroy
Posts: 1115
Joined: July 12, 2009, 3:52 am
Location: Melbourne, Australia
Australia

Re: fan conversion 66 f-100

Post by Leeroy »

Ive done this very conversion on my last slick (62) and am gathering the parts to do it on the next one (66.) The fan I used is a local product here in Australia and I don't think around on your side of the globe, so my writeup probably isn't much help, however you have a lot more to choose from!

One thing I will mention about the conversion is the load the fans put on a stock alternator. If you have a stock unit, it will not cope with 2 fans when at idle. Sure it will still fire up the fans and provide airflow but you WONT get the fans running at full speed when its idling (which is when you'll need it most!) I don't know your charging system, but if you have a stock alternator I'd be considering a 3G upgrade. They are dirt cheap over your side (I've imported 3 now from the same ebay seller in the US) and are relatively easy to hook up. It just needs some heavy duty wiring and a big a$$ mega fuse inline. I can help with the wiring setup if need be.

Controller is another question, last time I used some flash controller with adjustable points and a/c pickup etc. Probably a little OTT but it worked ok. They can be quite spendy depending on what you want to do with it, but there are lots to choose from. If you can, get one that has a step up or a spool up mode for the fans. They draw a significant load when they fire up and multiply that x2 for dual fans, mine was so high you could feel the engine stumble as the alt took up the load, and that was a 351!
bmcgc
Posts: 1391
Joined: March 25, 2012, 1:37 pm
Location: Macon, GA
United States of America

Re: fan conversion 66 f-100

Post by bmcgc »

I want to go electric to free up some hp. I have a 135a alternator already. My problem is that the PO put in a giant radiator and I have problems getting the truck up to temp so I can have some heat in the winter.
Over the hill and picking up speed!

1966 F100 (Mine)
1965 Mustang (Hers)
1965 Mustang (Hers)
2012 Dodge Caliber (Hers-under protest)
1998 1100 Aero (Hers)
2001 1100 Aero (Mine)

Wish List:

Win Indy 500
Ask Elvis WTH he has been
Spend the summer as Meatloafs Roadie
Be a member of the "Five Timers" club
Leeroy
Posts: 1115
Joined: July 12, 2009, 3:52 am
Location: Melbourne, Australia
Australia

Re: fan conversion 66 f-100

Post by Leeroy »

I have problems getting the truck up to temp
200 degree thermostat should fix that?
William-in-St George
Posts: 579
Joined: December 31, 2009, 5:26 pm
Location: Saint George Utah

Re: fan conversion 66 f-100

Post by William-in-St George »

Jerry I'd leave it be or switch to a clutch fan. The couple horses you may gain are unlikely to help much unless you are a racer. Bmcgc You can block some of the air flow through the radiator with a piece of cardboard on cold days. Just don't overdo it and keep an eye on the gauge. I like 190 thermostats if you have a 180 or a 160 that could be your problem.
William-in-St. George
BarnieTrk
Posts: 1448
Joined: July 11, 2007, 2:37 pm
Location: Stanton, Michigan

Re: fan conversion 66 f-100

Post by BarnieTrk »

William-in-St George wrote:Jerry I'd leave it be or switch to a clutch fan. The couple horses you may gain are unlikely to help much unless you are a racer. Bmcgc You can block some of the air flow through the radiator with a piece of cardboard on cold days. Just don't overdo it and keep an eye on the gauge. I like 190 thermostats if you have a 180 or a 160 that could be your problem.
I agree 110% ^^^^^ .... :thumright:

BarnieTrk :2cents:
Post Reply